The product strictly complies with international IEC 60146 Semiconductor Converters, GB/T 3859.1-2013 Semiconductor Converters - General Requirements and Power Grid Converters and industry standard T/CES 242-2023 Technical Specification for Power Supply of Alkaline Electrolytic Cell and other authoritative specifications, supports voltage stabilization (accuracy ≤ ± 0.5%) and current stabilization (accuracy ≤ ± 0.3%) dual mode switching, meets strict requirements of PEM electrolyzer on dynamic response, integrates soft start (0-180 seconds adjustable), overvoltage/undervoltage protection, overcurrent/short circuit protection, overheating protection and fault restart functions, adopts dual DSP architecture and three-level protection (overvoltage/overcurrent/overheating), average time between failures (MTMT). BF) up to 50000 hours, millisecond load step response, fast suppression of voltage fluctuation during electrolysis.
Standard touch screen, historical data query, multi-protocol communication interface, compatible with PLC remote control and cloud big data analysis, insulation monitoring device, real-time monitoring of electrolytic cell leakage current, positive and negative reversing controller, applicable to bipolar electrolysis process. It can be widely used in electrolytic water to produce hydrogen, electrolytic water to produce chlorine, fluorine gas electrolytic purification, rare gas purification, carbon dioxide electrolysis, ammonia electrolysis, synthesis gas (CO+H2) co-electrolysis and other scenes.

| Model | Parameter |
|---|---|
| Input voltage class | Low power: three-phase 380VAC/480VAC ± 10% High power: customized high voltage (e.g. 10KV/35KV, applicable to industrial power grid) |
| Frequency range | 45~65HzSelf-adaption |
| Power supply efficiency | ≥95%(Full load working condition) |
| Power factor | ≥0.96(Full load working condition) |
| Harmonics ITHD | ≤5% |
| Heat dissipation mode | Pure air cooling (customized water cooling) |
| Operating temperature | -40℃~+50℃(Wide temperature range adaptation) |
| Relative humidity | ≤90%,No condensation |